Â
Calibration Instructions:
- Install Autel OA Calibration Tool on your PC / Mac
- Connect EVO II to your PC with USB-C cable
- Power on EVO II
- Run Autel Vision Assistant Program and wait for the connection, which may take up to 1 minute (if you wait for more than 1 minute and no response, please follow the steps below for troubleshooting)
- Close the Autel Vision Assistant and reopen
- Change your network IP address and avoid using 192.168.1.11, or disable your internet while using the calibration tool
- If a warning message is displayed indicating your CPU is not powerful enough for the calibration use a different PC
- Once connected, you will see the current status of all the sensors
- Select the first sensor requiring the auto-calibration to initiate calibration
- Follow the instructions in the top left corner of the screen, hold your EVO2 and aim the corresponding sensor at the screen as indicated
- Once all calibration steps on-screen are completed the results are auto-updated on your EVO II
- Repeat steps 6-8 until you have completed the auto-calibration for all indicated sensors